Product Smart policing
FC1500 Handheld Liquid Detector
Inquire
N-TET
  • Product Introduction
  • Features
  • Technical indicators
Contact us

010-83622127

info@n-tetbj.com

return

Product Introduction

The FC1500 handheld hazardous liquid safety detector is a security inspection instrument specifically designed for detecting flammable and explosive liquids. It is small in size, analyzes quickly, and is easy to operate. It can rapidly identify flammable and explosive liquids without contact with them and is widely used in security checks at stations, subways, airports, government agencies, and large sporting events.

Features

  • 01
    Convenience: The product is lightweight; easy to use; portable; and allows for rapid detection.
  • 02
    Security: Accurate and rapid identification; microwave detection; LCD screen display
  • 03
    Novelty: Portable; ready to use after simple training; can detect not only sulfuric acid, hydrochloric acid and other flammable and hazardous liquids, but also nitromethane, a major raw material for liquid explosives.
  • 04
    Applications: This detector is the world's first instrument designed to detect liquid explosives and hazardous liquids. It primarily detects flammable and explosive liquids such as nitromethane, sulfuric acid, hydrochloric acid, and gasoline, and can minimize the risk of loss of life and property damage caused by liquid bombs.
  • 05
    Preventing Terrorist Attacks: While major public places such as airports, subways, and train stations have instruments for preventing terrorist attacks, such as metal detectors and explosive detectors, detectors for detecting hazardous liquids are rare. Using this product can better ensure safety.
  • 06
    Fire Prevention: Most fire-fighting equipment installed on major public transportation facilities activates after a fire has broken out. There are virtually no fire detectors that can prevent or stop a fire before it occurs. This product offers a cost-effective way to achieve excellent fire prevention results.

Technical indicators

Basic parameters
Self-verification function have
Detection principle microwave method
Identification method Identification of the physical properties (conductivity, resistance) of the tested object
Detection response time 1 second to 2.5 seconds
Startup 1 second
The detection results show Displayed on an LCD screen and accompanied by an alarm sound.
Automatic time verification 5 seconds
Detectable species Gasoline, kerosene, diesel, diethyl ether, isopropyl ether, petroleum ether, acetonitrile, ethylene glycol, nitrobenzene, propylene oxide, n-heptane, turpentine, acetone, benzene, toluene, xylene, dichloroethane, ethanol, isopropanol, n-octane, carbon disulfide, methanol, nitromethane, n-hexane, chloroform, paint thinner (nitro thinner solvent), tetrahydrofuran, paint, styrene, cyclohexanone, cyclopentane, diethylamine, n-pentane, tert-butanol, methyl acrylate, n-propanol, cyclohexane, methyl tert-butyl ether, 1,4-dioxane, dipentene, acetaldehyde, pyrrolidine, and more than forty other flammable and explosive hazardous liquids.
Ambient temperature 0℃~+50℃
relative humidity 0 to 95% RH
Power supply method Rechargeable battery or 220V power supply
Battery Type Lithium-ion batteries
Number of tests after a full charge ≥1250 times
Power consumption ≦0.35A
composition Main unit, charging dock, etc.
Main dimensions L216W50H79 mm
weight Approximately 199.5 grams (including battery)
Container size can be detected Size no smaller than 5.5cm x 1.5cm, minimum capacity 50ml
Alarm methods Audible alarm, LCD graphic display alarm
Human-computer interface Fully Chinese interface, self-emissive OLED screen display
Data storage It has a storage capacity of at least 10,000 tests and can export data via USB interface.
Operating temperature range -10℃-+55℃

Online message